Self-adhesive label low temperature resistance test

Low temperatures can affect both label application and the performance of the finished bond. Adhesive, substrate, moisture and the temperature history should be considered together when selecting and testing a construction.

Two temperatures, not one

ParameterWhat it means
Minimum application temperatureThe coldest surface the adhesive can still bond to at the moment of application
Service temperatureThe coldest condition the finished bond can survive once formed

A label may require a warmer application surface than its eventual service temperature. Confirm both limits, exposure duration and suitability for the complete label construction with the material specification and application tests.

Method

ItemCondition
SubstratesHDPE, PP, corrugated board, glass, or the customer’s own packaging
ApplicationApplication temperature and substrate condition agreed for the project
StorageStorage temperature, duration and any cycles agreed for the intended use
Wet-cold variantCondensation or moisture exposure included when relevant and agreed
AssessedEdge lift, corner curl, peel and print or barcode legibility as agreed in the test plan

Typical cold-chain cases

  • Chilled +4 °C — dairy, fresh meat and suitable cold-chain packaging; consider condensation
  • Frozen −18 °C — retail frozen food, ice cream, corrugated outer cases
  • Deep freeze −40 °C and below — laboratory samples, specialist logistics
  • Freeze–thaw cycling — consider repeated temperature and moisture changes

Corrugated board is porous and its surface can vary. When required, evaluate the selected label on the actual board and under the relevant application and storage conditions.

Related: Blood bag labels · PET labels · Label Laboratory

Scroll to Top